Journal article
A brief effective screening protocol for identifying cataract patients with binocular vision anomalies
BMC ophthalmology, v 24(1), 536
18 Dec 2024
PMID: 39695508
Featured in Collection : UN Sustainable Development Goals @ Drexel
Abstract
To compare the effectiveness of a brief binocular vision screening protocol to a comprehensive examination for detecting binocular vision anomalies before and after cataract surgery.
A comprehensive binocular vision test battery as a gold standard were administered on recruited patients before the first surgery and at the third visit after surgery on the second eye. A receiver operating characteristic (ROC) curve was plotted to illustrate the diagnostic ability of each test. In addition, a univariate logistic regression analysis was performed to further determine the contribution of each preoperative test to the prediction of pre- and post-surgical binocular vision anomalies.
Significant differences were shown for the difference in phoria from distance to near measured by the cover test (Area Under Curve [AUC] = 0.96, P < 0.01), step vergence testing of positive fusional vergence at distance (AUC = 0.71, P < 0.01) and near (AUC = 0.77, P < 0.01). The other tests did not show statistically significant differences. The ROC curve generated by combining the difference in distance and near phoria with positive fusional vergence at both distance and near demonstrated a more robust measure of diagnostic accuracy. (AUC = 0.98, P < 0.01).
Distance and near phoria difference measured by cover test has similar effectiveness as a comprehensive binocular vision testing protocol for the diagnosis of binocular vision anomalies. Distance and near positive fusional vergence measured by step vergence testing also have significant predictive value. A combination of the two tests is an outstanding screening protocol for binocular vision anomalies before cataract surgery.
The study was registered at ClinicalTrials.gov (NCT03592615, Date of registration: July 19, 2018).
Metrics
2 Record Views
Details
- Title
- A brief effective screening protocol for identifying cataract patients with binocular vision anomalies
- Creators
- Qing-Qing Tan - Salus UniversityJia-Hao Tan - North Sichuan Medical UniversityChang-Kang Luo - North Sichuan Medical UniversityChun-Yan Lai - North Sichuan Medical UniversityWei Zhao - North Sichuan Medical UniversityChang-Jun Lan - Chengdu Eastern Aier Eye Hospital, Chengdu, Sichuan, ChinaJames Lewis - Salus UniversitySaeed Aljohani - Qassim UniversityXuan Liao - Affiliated Hospital of North Sichuan Medical CollegeMitchell Scheiman - Salus University
- Publication Details
- BMC ophthalmology, v 24(1), 536
- Publisher
- BMC
- Number of pages
- 8
- Grant note
- CBY20-QD05 / the Doctoral Research Foundation Project of North Sichuan Medical College
- Resource Type
- Journal article
- Language
- English
- Academic Unit
- Biomedicine; Pennsylvania College of Optometry (PCO)
- Web of Science ID
- WOS:001380998600010
- Scopus ID
- 2-s2.0-85212403024
- Other Identifier
- 991022005739304721
UN Sustainable Development Goals (SDGs)
This publication has contributed to the advancement of the following goals:
InCites Highlights
Data related to this publication, from InCites Benchmarking & Analytics tool:
- Collaboration types
- Domestic collaboration
- International collaboration
- Web of Science research areas
- Ophthalmology