Journal article
A highly sensitive and specific workflow for detecting rare copy-number variants from exome sequencing data
GENOME MEDICINE, v 12(1), 14
30 Jan 2020
PMID: 32000839
Featured in Collection : UN Sustainable Development Goals @ Drexel
Abstract
Background Exome sequencing (ES) is a first-tier diagnostic test for many suspected Mendelian disorders. While it is routine to detect small sequence variants, it is not a standard practice in clinical settings to detect germline copy-number variants (CNVs) from ES data due to several reasons relating to performance. In this work, we comprehensively characterized one of the most sensitive ES-based CNV tools, ExomeDepth, against SNP array, a standard of care test in clinical settings to detect genome-wide CNVs. Methods We propose a modified ExomeDepth workflow by excluding exons with low mappability prior to variant calling to drastically reduce the false positives originating from the repetitive regions of the genome, and an iterative variant calling framework to assess the reproducibility. We used a cohort of 307 individuals with clinical ES data and clinical SNP array to estimate the sensitivity and false discovery rate of the CNV detection using exome sequencing. Further, we performed targeted testing of the STRC gene in 1972 individuals. To reduce the number of variants for downstream analysis, we performed a large-scale iterative variant calling process with random control cohorts to assess the reproducibility of the CNVs. Results The modified workflow presented in this paper reduced the number of total variants identified by one third while retaining a higher sensitivity of 97% and resulted in an improved false discovery rate of 11.4% compared to the default ExomeDepth pipeline. The exclusion of exons with low mappability removes 4.5% of the exons, including a subset of exons (0.6%) in disease-associated genes which are intractable by short-read next-generation sequencing (NGS). Results from the reproducibility analysis showed that the clinically reported variants were reproducible 100% of the time and that the modified workflow can be used to rank variants from high to low confidence. Targeted testing of 30 CNVs identified in STRC, a challenging gene to ascertain by NGS, showed a 100% validation rate. Conclusions In summary, we introduced a modification to the default ExomeDepth workflow to reduce the false positives originating from the repetitive regions of the genome, created a large-scale iterative variant calling framework for reproducibility, and provided recommendations for implementation in clinical settings.
Metrics
Details
- Title
- A highly sensitive and specific workflow for detecting rare copy-number variants from exome sequencing data
- Publication Details
- GENOME MEDICINE, v 12(1), 14
- Publisher
- BMC; LONDON
- Grant note
- This work is supported by the National Institutes of Health grant R01-HG009708 and U01-HG006546.
- Resource Type
- Journal article
- Language
- English
- Academic Unit
- Drexel University
- Web of Science ID
- WOS:000512015600002
- Scopus ID
- 2-s2.0-85078712817
- Other Identifier
- 991021860779204721
UN Sustainable Development Goals (SDGs)
This publication has contributed to the advancement of the following goals:
InCites Highlights
Data related to this publication, from InCites Benchmarking & Analytics tool:
- Collaboration types
- Domestic collaboration
- Web of Science research areas
- Genetics & Heredity