Logo image
A novel method to control P+/P- ratio of the shock wave pulses used in the extracorporeal piezoelectric lithotripsy (EPL)
Journal article   Peer reviewed

A novel method to control P+/P- ratio of the shock wave pulses used in the extracorporeal piezoelectric lithotripsy (EPL)

Peter A. Lewin, Jean-Yves Chapelon, Jean-Louis Mestas, Alain Birer and Dominique Cathignol
Ultrasound in medicine & biology, v 16(5), pp 473-488
1990
PMID: 2238254

Abstract

Focused waves Nonlinear acoustic propagation Piezoelectric lithotripsy PVDF hydrophones Shock waves Ultrasound
There is growing evidence that acoustic cavitation plays an important role in stone fragmentation during extracorporeal shock wave lithotripsy (ESL) treatment. In addition, side effects of the treatment, such as the hemorrhage and destruction of the tissue in the vicinity of the stone are also ascribed to cavitation phenomenon. Since cavitation is associated with the maximum negative pressure in the shock pulse, it would thus appear that possibility of controlling this pressure would be desirable in ESL applications. This paper describes a novel technique developed to control the ratio of compressional peak (P+) to rarefactional peak pressure (P-) of the shock wave for use in lithotripsy treatment. The procedure is based on the finite amplitude wave generation by focused piezoelectric transducers and subsequent interaction of the shocked waves in the common focal region. The highly asymmetrical shock wave is produced in the focal region by providing an appropriate time delay to each of the high voltage electrical excitation signals which drive the transducers. The degree of relative reduction of negative halfcycles and the corresponding positive halfcycles amplification increases with the number of the acoustic sources used. The practical implementation of the shock wave generator was obtained by using 5 cm diameter, focused 1 MHz transmitter, and additional transducers of identical construction having frequencies corresponding to the harmonics and subharmonics of the 1 MHz frequency. The importance of the results for the future development of lithotripters, and stone treatment efficiency is pointed out.

Metrics

16 Record Views
13 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Domestic collaboration
International collaboration
Web of Science research areas
Acoustics
Radiology, Nuclear Medicine & Medical Imaging
Logo image