Logo image
Acousto-optic, point receiver hydrophone probe for operation up to 100 MHz
Journal article   Peer reviewed

Acousto-optic, point receiver hydrophone probe for operation up to 100 MHz

P. A Lewin, C MU, S Umchid, A Daryoush and M EL-SHERIF
Ultrasonics, v 43(10), pp 815-821
Dec 2005
PMID: 16054665

Abstract

Exact sciences and technology Fundamental areas of phenomenology (including applications) Transduction; acoustical devices for the generation and reproduction of sound Ultrasonics, quantum acoustics, and physical effects of sound Acoustics Physics
This work describes the results of initial evaluation of a wideband acousto-optic hydrophone probe designed to operate as point receiver in the frequency range up to 100 MHz. The hydrophone was implemented as a tapered fiber optic (FO) probe sensor with a tip diameter of approximately 7 μm. Such small physical dimensions of the sensor eliminate the need for spatial averaging corrections so that true pressure–time (p–t) waveforms can be faithfully recorded. The theoretical considerations that predicted the FO probe sensitivity to be equal to 4.3 mV/MPa are presented along with a brief description of the manufacturing process. The calibration results that verified the theoretically predicted sensitivity are also presented along with a brief description of the improvements being currently implemented to increase this sensitivity level by approximately 20 dB. The results of preliminary measurements indicate that the fiber optic probes will exhibit a uniform frequency response and a zero phase shift in the frequency range considered. These features might be very useful in rapid complex calibration i.e. determining both magnitude and phase response of other hydrophones by the substitution method. Also, because of their robust design and linearity, these fiber optic hydrophones could also meet the challenges posed by high intensity focused ultrasound (HIFU) and other therapeutic applications. Overall, the outcome of this work shows that when fully developed, the FO probes will be well suited for high frequency measurements of ultrasound fields and will be able to complement the data collected by the current finite aperture piezoelectric PVDF hydrophones.

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Web of Science research areas
Acoustics
Radiology, Nuclear Medicine & Medical Imaging
Logo image