- Title
- Doppler echocardiographic evaluation of left ventricular diastolic filling hemodynamics as related to ejection performance in patients with normally and abnormally functioning St. Jude medical prosthesis in the mitral valve position
- Creators
- JIAN-FANG Ren - Hahnemann univ., Likoff cardiovascular inst., Philadelphia PA, United StatesG. S Mintz - Hahnemann univ., Likoff cardiovascular inst., Philadelphia PA, United StatesM Mcallister - Hahnemann univ., Likoff cardiovascular inst., Philadelphia PA, United StatesR. S Pennock - Hahnemann univ., Likoff cardiovascular inst., Philadelphia PA, United StatesW. S Frankl - Hahnemann univ., Likoff cardiovascular inst., Philadelphia PA, United States
- Publication Details
- Journal of cardiovascular technology (New York, NY), Vol.9(4), pp.339-349
- Publisher
- Liebert
- Resource Type
- Journal article
- Language
- English
- Academic Unit
- Product Design
- Identifiers
- 991019173548704721
Journal article
Doppler echocardiographic evaluation of left ventricular diastolic filling hemodynamics as related to ejection performance in patients with normally and abnormally functioning St. Jude medical prosthesis in the mitral valve position
Journal of cardiovascular technology (New York, NY), Vol.9(4), pp.339-349
1990
Abstract
Metrics
1 Record Views