Logo image
Effect of Nucleus Replacement Device Properties on Lumbar Spine Mechanics
Journal article

Effect of Nucleus Replacement Device Properties on Lumbar Spine Mechanics

Steven A. Rundell, Heather L. Guerin, Joshua D. Auerbach and Steven M. Kurtz
Spine (Philadelphia, Pa. 1976), v 34(19), pp 2022-2032
01 Sep 2009
PMID: 19730210

Abstract

Clinical Neurology Life Sciences & Biomedicine Neurosciences & Neurology Orthopedics Science & Technology
Study Design. A validated nonlinear three-dimensional finite element model of a single lumbar motion segment (L3-L4) was used to evaluate a range of moduli for ideally conforming nucleus replacement devices. Objective. The objective of the current study was to determine the biomechanical effects of nucleus replacement technology for a variety of implant moduli. We hypothesized that there would be an optimal modulus for a nucleus replacement that would provide loading in the surrounding bone and anulus similar to the intact state. Summary of Background Data. Nucleus pulposus replacements are interventional therapies that restore stiffness and height to mildly degenerated intervertebral discs. Currently a wide variety of nucleus replacement technologies with a large range of mechanical properties are undergoing preclinical testing. Methods. A finite element model of L3-L4 was created and validated using range of motion, disc pressure, and bony strains from previously published data. The intact model was altered by changing the mechanical properties of the nucleus pulposus to represent a wide range of nucleus replacement technologies (E = 0.1, 1, 4, and 100 MPa). All of the models were exercised in compression, flexion, extension, lateral bending, and axial rotation. Vertebral body strain, peak anulus fibrosus shear strain, initial bone remodeling stimulus, range of motion, and center of rotation were analyzed. Results. A nucleus replacement modulus of 1 and 4 MPa resulted in vertebral body strains similar to the intact model. The softest device indicated increased loading in the AF and bone resorption adjacent to the implant. Areas of strain maxima and bone formation were observed adjacent to the implant for the stiffest device. Conclusion. The current study predicted an optimal nucleus replacement of 1 to 4 MPa. An overly stiff implant could result in subsidence, which would preclude the benefit of disc height increase or restoration. Conversely, an overly soft implant could accelerate a degenerative cascade in the anulus.

Metrics

9 Record Views
23 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Industry collaboration
Domestic collaboration
Web of Science research areas
Clinical Neurology
Orthopedics
Logo image