Journal article
Electrochemical removal of hexavalent chromium using electrically conducting carbon nanotube/polymer composite ultrafiltration membranes
Journal of membrane science, v 531, pp 160-171
01 Jun 2017
Featured in Collection : UN Sustainable Development Goals @ Drexel
Abstract
Hexavalent chromium (Cr(VI)) contamination in drinking water resources remains a challenge in many parts of the United States, as well as in regions affected by industrial pollution. In this study, we demonstrated how electrically conducting carbon nanotube (CNT) - polyvinyl alcohol (PVA) composite ultrafiltration (UF) membranes can be used to remove Cr(VI) from water through a combined process of electrostatic repulsion, electrochemical reduction, and precipitation. The impact of different operational (flux, contact time, applied electrical potential) and environmental (pH and salinity) conditions on Cr(VI) removal were evaluated. Due to the native electrical potential of the CNT/PVA UF membrane material, approximately 45% removal of 1 ppm Cr(VI) solution was detected under neutral pH conditions in deionized water. Increased Cr(VI) removal was observed with increasing membrane surface charge density, which was accomplished through the application of an external potential (3 V, 5 V and 7 V, membrane as cathode) to the electrically conductive membrane surface. The solution ionic strength showed a significant impact on Cr(VI) removal. By increasing the ionic strength without applying external potential on the membrane, the electrostatic repulsive force between the charged membrane surface and the CrO42- ion was eliminated, and Cr(VI) removal dropped to zero. The highest removal (95%) was achieved when 7 V was applied to the membrane/counter electrode with a 6 Inn-thick membrane. Here, Cr(VI) was electrochemically reduced to Cr(III) on the membrane surface, followed by Cr(III) precipitation as chromium hydroxide Cr(OH)(3(s)), which occurred by Cr(III) reacting with hydroxide ions generated via water splitting on the CNT network. Precipitated Cr(OH)3 was then removed by the UF membrane. In addition, CNT-PVA UF membranes were used to treat tap water spiked with Cr(VI); under these conditions, 99% Cr(VI) removal was observed when 7 V were applied to the membrane/counter electrode. Furthermore, we demonstrate that other trace inorganic contaminants, such as uranium, were effectively removed as well.
Metrics
Details
- Title
- Electrochemical removal of hexavalent chromium using electrically conducting carbon nanotube/polymer composite ultrafiltration membranes
- Creators
- Wenyan Duan - University of California, RiversideGongde Chen - University of California, RiversideChuxiao Chen - University of California, RiversideRiya Sanghvi - University of California, RiversideArpita Iddya - University of California, RiversideSharon Walker - University of California, RiversideHaizhou Liu - University of California, RiversideAvner Ronen - Temple CollegeDavid Jassby - University of California, Riverside
- Publication Details
- Journal of membrane science, v 531, pp 160-171
- Publisher
- Elsevier
- Number of pages
- 12
- Grant note
- 54649-dni9 / ACS Petroleum Research Fund; American Chemical Society; American Cancer Society 1553756; DMR-0958796 / National Science Foundation; National Science Foundation (NSF) n00014-14-1-0809 / Office of Naval Research
- Resource Type
- Journal article
- Language
- English
- Academic Unit
- College of Engineering
- Web of Science ID
- WOS:000400228700018
- Scopus ID
- 2-s2.0-85015041888
- Other Identifier
- 991021229984704721
UN Sustainable Development Goals (SDGs)
This publication has contributed to the advancement of the following goals:
InCites Highlights
Data related to this publication, from InCites Benchmarking & Analytics tool:
- Collaboration types
- Domestic collaboration
- Web of Science research areas
- Engineering, Chemical
- Polymer Science