Logo image
Finite Element Static Displacement Optimization of 20–100 kHz flexural transducers for fully portable ultrasound applicator
Journal article   Open access   Peer reviewed

Finite Element Static Displacement Optimization of 20–100 kHz flexural transducers for fully portable ultrasound applicator

Christopher R. Bawiec, Youhan Sunny, An T. Nguyen, Joshua A. Samuels, Michael S. Weingarten, Leonid A. Zubkov and Peter A. Lewin
Ultrasonics, v 53(2), pp 511-517
14 Sep 2012
PMID: 23040829
url
https://europepmc.org/articles/pmc3568635View
Accepted (AM)Open Access (License Unspecified) Open

Abstract

design optimization Low frequency (<100 kHz) ultrasound transducers therapeutic ultrasound wearable ultrasound patch Finite Element Analysis
This paper focuses on the development of a finite-element model and subsequent stationary analysis performed to optimize individual flexural piezoelectric elements for operation in the frequency range of 20–100 kHz. These elements form the basic building blocks of a viable, un-tethered, and portable ultrasound applicator that can produce intensities on the order of 100 mW/cm 2 spatial-peak temporal-peak (I SPTP ) with minimum (on the order of 15 V) excitation voltage. The ultrasound applicator can be constructed with different numbers of individual transducer elements and different geometries such that its footprint or active area is adjustable. The primary motivation behind this research was to develop a tether-free, battery operated, fully portable ultrasound applicator for therapeutic applications such as wound healing and non-invasive transdermal delivery of both naked and encapsulated drugs. It is shown that careful selection of the components determining applicator architecture allows the displacement amplitude to be maximized for a specific frequency of operation. The work described here used the finite-element analysis software COMSOL to identify the geometry and material properties that permit the applicator’s design to be optimized. By minimizing the excitation voltage required to achieve the desired output (100 mW/cm 2 I SPTP) the power source (rechargeable Li-Polymer batteries) size may be reduced permitting both the electronics and ultrasound applicator to fit in a wearable housing [1].

Metrics

5 Record Views
19 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Web of Science research areas
Acoustics
Radiology, Nuclear Medicine & Medical Imaging
Logo image