Green roof thermal buffering: Insights derived from fixed and portable monitoring equipment
Journal article   Peer reviewed

Green roof thermal buffering: Insights derived from fixed and portable monitoring equipment

J. Alvizuri, J. Cataldo, L. A. Smalls-Mantey and F. A. Montalto
Energy and buildings, v 151, pp 455-468
15 Sep 2017

Abstract

Construction & Building Technology Energy & Fuels Engineering Engineering, Civil Science & Technology Technology
Thermal buffering of the 27,316 m(2) Jacob K. Javits Convention Center Green Roof (JJCC Green Roof) was investigated in the field, as well as in the laboratory in order to determine its ability to insulate a building. An instrumented replica of the green roof cross section was developed to elucidate the inner-workings of the system. During the course of a year a total of twelve field monitoring campaigns were conducted to measure temperatures with 249 images collected at sixteen different locations (eight exterior and eight interior). During this first sequence of measurements, the north green roof had already been completed, while the south green roof was gradually being installed. Additional field imaging was performed on two separate days in August (on 08/08/15,08/22/15), and on one day in January (on 01/22/16) between sunrise and sunset (generating an additional 850 images). To isolate the thermal performance of individual components of the roof structure, a physical model of the roof was constructed in a laboratory, instrumented with thermistors, and subjected to a heat lamp. A one-dimensional heat conduction model was used to investigate physical relationships revealed by the field and laboratory observations, and represents the experimental data well. The results indicate that the construction of the green roof significantly reduces heat flux through the convention center roof. The mean internal and external temperatures on the north and south sections of the roof on the first monitoring day (when the north green roof was complete, but the south green roof had not yet been installed) and the last monitoring day (when both north and south green roof sections were complete) are provided to support the insulating value of the green roof layers. The mean exterior temperature on the south roof on the first day of monitoring was 53.9 degrees C and 37 degrees C on the north roof. The mean exterior temperature on the south roof on the last day of monitoring was 24 degrees C and the north roof 28 degrees C. (C) 2017 Elsevier B.V. All rights reserved.

Metrics

7 Record Views
18 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#11 Sustainable Cities and Communities
#13 Climate Action

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Web of Science research areas
Construction & Building Technology
Energy & Fuels
Engineering, Civil
Logo image