Logo image
Has Hypofractionated Whole-Breast Radiation Therapy Become the Standard of Care in the United States? An Updated Report from National Cancer Database
Journal article   Open access   Peer reviewed

Has Hypofractionated Whole-Breast Radiation Therapy Become the Standard of Care in the United States? An Updated Report from National Cancer Database

Minji M. Kang, Yasmin Hasan, Joseph Waller, Loren Saulsberry and Dezheng Huo
Clinical breast cancer, v 22(1), pp e8-e20
01 Jan 2022
PMID: 34257001
url
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8934112View
Accepted (AM) Open PubMed Central

Abstract

Barriers Hypofractionated radiation therapy Trend Utilization Breast Cancer
We aimed to update the previous evaluation of hypofractionated whole-breast irradiation (HF-WBI) use over time in the United States and factors related to its adoption for patients undergoing a lumpectomy from 2004 to 2016. Among the patients who underwent a lumpectomy, we identified 688,079 patients with early-stage invasive breast cancer and 248,218 patients with ductal carcinoma in situ in the National Cancer Database from 2004 to 2016. We defined HF-WBI as 2.5 to 3.33 Gy/fraction to the breast and conventional fractionated whole-breast irradiation as 1.8 to 2.0 Gy/fraction. We evaluated the trend of HF-WBI use and examined factors associated with HF-WBI use using logistic regression models. Among invasive cancer patients, the use of HF-WBI increased exponentially from 0.7% in 2004 to 15.6% in 2013 and then to 38.1% in 2016. Among patients with ductal carcinoma in situ, the use of HF-WBI has increased significantly from 0.42% in 2004 to 13.4% in 2013 and then to 34.3% in 2016. Factors found to be associated with HF-WBI use included age, patient geographical location, race/ethnicity, tumor stage, grade, treating facility type, and volume. HF-WBI use in the United States has more than doubled from 2013 to 2016. Although its use is close to that of conventional fractionated whole-breast irradiation, HF-WBI is still far from the preferred standard of care in the United States. We identified several patient and facility factors that can impact the uptake of HF-WBI treatment. Microabstract Using the National Cancer Database from 2004 to 2016, we evaluated the trend of hypofractionated whole-breast radiation therapy use and factors associated with use. Use in the United States has more than doubled from 2013 to 2016, but it has not become the standard of care. We identified several patient and facility factors that impact the uptake of hypofractionated whole-breast radiation therapy treatment. Using the National Cancer Database from 2004-2016, we evaluated the trend of hypofractionated whole breast radiation therapy (HF-WBI) utilization and factors associated with utilization. Utilization in the United States has more than doubled from 2013 to 2016, but it has not become the standard of care. We identified several patient and facility factors that impact the uptake of HF-WBI treatment.

Metrics

9 Record Views
13 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: SDGs in the Output

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Domestic collaboration
Web of Science research areas
Oncology
Logo image