In vitro ultrasound-mediated leakage from phospholipid vesicles

Mona Pong, Sumet Umchid, Andrew Joseph Guarino, Peter A. Lewin, Jerzy Litniewski, Andrzej Nowicki and S. Wrenn
Ultrasonics, v 45(1–4)
Dec 2006
pdf
idea_1643_OBJ326.98 kBDownloadView
Accepted (AM) Open Access

Abstract

Ultrasound exposure Therapeutic ultrasound Membrane permeability Giant vesicles PEG2000
Interest in using ultrasound energy in wound management and intracellular drug delivery has been growing rapidly. Development and treatment optimization of such non-diagnostic applications requires a fundamental understanding of interactions between the acoustic wave and phospholipid membranes, be they cell membranes or liposome bilayers. This work investigates the changes in membrane permeation (leakage mimicking drug release) in vitro during exposure to ultrasound applied in two frequency ranges: "conventional" (1 MHz and 1.6 MHz) therapeutic ultrasound range and low (20 kHz) frequency range. Phospholipids vesicles were used as controllable biological membrane models. The membrane properties were modified by changes in vesicle dimensions and incorporation of poly(ethylene glycol) i.e. PEGylated lipids. Egg phosphatidylcholine vesicles with 5 mol % PEG were prepared with sizes ranging from 100 nm to 1 μm. Leakage was quantified in terms of temporal fluorescence intensity changes observed during carefully controlled ultrasound ON/OFF time intervals. Custom-built transducers operating at frequencies of 1.6 MHz (focused) and 1.0 MHz (unfocused) were used, the Ispta of which were 46.9 W/cm2 and 3.0 W/cm2, respectively. A commercial 20 kHz, point-source, continuous wave transducer with an Ispta of 0.13 W/cm2 was also used for comparative purposes. Whereas complete leakage was obtained for all vesicle sizes at 20 kHz, no leakage was observed for vesicles smaller than 100 nm in diameter at 1.6 or 1.0 MHz. However, introducing leakage at the higher frequencies became feasible when larger (greater than 300 nm) vesicles were used, and the extent of leakage correlated well with vesicle sizes between 100 nm and 1 μm. This observation suggests that physico-chemical membrane properties play a crucial role in ultrasound mediated membrane permeation and that low frequency (tens of kilohertz) ultrasound 3 exposure is more effective in introducing permeability change than the "conventional" (1 MHz) therapeutic one. The experimental data also indicate that the leakage level is controlled by the exposure time. The results of this work might be helpful to optimize acoustic field and membrane parameters for gene or drug delivery. The outcome of this work might also be useful in wound management.

Metrics

31 File views/ downloads
49 Record Views
57 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Domestic collaboration
International collaboration
Web of Science research areas
Acoustics
Radiology, Nuclear Medicine & Medical Imaging
Logo image