Logo image
Influence of Spinal Bridging Ossification on Mechanical Properties and Fracture Tolerance Under Flexion/Extension Loading
Journal article   Peer reviewed

Influence of Spinal Bridging Ossification on Mechanical Properties and Fracture Tolerance Under Flexion/Extension Loading

Elizabeth A. Rapp van Roden, Corinne N. Riggin, Derek T. Holyoak, Dhara Amin, Patrick Hall, Juan Jose Paredes, Cynthia Day, Kathleen A. Rodowicz, Ryan Siskey and Michael R. Carhart
Annals of biomedical engineering, v 53(10), pp 2679-2688
01 Oct 2025
PMID: 40658299

Abstract

Engineering, Biomedical Science & Technology Engineering Technology
PurposeDiffuse idiopathic skeletal hyperostosis (DISH) is characterized by "flowing" ossifications that form along the anterolateral aspect of contiguous vertebrae. While prior literature has identified that DISH patients are susceptible to spinal injury, the DISH-specific differences in mechanical response of human spines to applied bending have not been quantified. Therefore, the purpose of this work was to assess the effect of DISH on range of motion, stiffness, and fracture tolerance under flexion/extension loading.MethodsSeven human cadaveric spines were dissected into specimens composed of three functional spinal units (3FSUs), spanning levels T1-T4, T5-T8, and T9-T12. For each 3FSU specimen, the presence of bridging DISH ossification was determined. Ten DISH-affected and eleven normal specimens were evaluated under flexion/extension range of motion followed by extension to failure/system limits.ResultsDISH-affected specimens had significantly less range of motion compared to normal specimens (1.8 deg vs. 3.2 deg, p = 0.0125) and were significantly stiffer (5.5 N<middle dot>m/deg vs. 2.9 N<middle dot>m/deg, p = 0.0167). All DISH-affected specimens fractured during extension to failure, whereas five normal specimens did not fracture under the test loading. Hazard ratio analyses indicated that DISH-affected specimens are four times more likely to fracture compared to normal specimens under a given torque and sixteen times more likely for a given extension angle. The normal specimen median energy at fracture was significantly greater than the DISH-affected group (301 Nm<middle dot>deg vs. 81 Nm<middle dot>deg, p = 0.006).ConclusionThis study demonstrates a significant increase in the injury potential of DISH spines during bending loading and provides the first quantitative support for clinical observations of compromised fracture tolerance within the DISH population. Future work classifying the severity of DISH in the context of mechanical response may assist in radiological identification of otherwise asymptomatic patients with increased potential for injury.

Metrics

1 Record Views

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: SDGs in the Output

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Industry collaboration
Domestic collaboration
Web of Science research areas
Engineering, Biomedical
Logo image