Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners?
Journal article   Open access   Peer reviewed

Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners?

Guy Cafri, Elizabeth W. Paxton, Rebecca Love, Stefano A. Bini and Steven M. Kurtz
Clinical orthopaedics and related research, v 475(5), pp 1349-1355
01 May 2017
PMID: 27385222
url
https://doi.org/10.1007/s11999-016-4966-1View
Published, Version of Record (VoR)Maybe Open Access (Publisher Bronze) Open

Abstract

Life Sciences & Biomedicine Orthopedics Science & Technology Surgery
Background The most common bearing surface used among primary THAs worldwide is a metal or ceramic femoral head that articulates against a highly crosslinked ultrahigh-molecular-weight polyethylene (HXLPE) acetabular liner. Despite their widespread use, relatively little is known about the comparative effectiveness of ceramic versus metal femoral heads with respect to risk of revision and dislocation as well as the role of head size in this relationship. Questions/purposes The purpose of this study was to evaluate the risk of (1) all-cause revision in metal versus ceramic femoral heads when used with an HXLPE liner, including an evaluation of the effect of head size; and (2) dislocation in metal versus ceramic femoral heads when used with an HXLPE liner as well as an assessment of the effect of head size. Methods Data were collected as part of the Kaiser Permanente Total Joint Replacement Registry between 2001 and 2013. Patients in this study were on average overweight (body mass index = 29 kg/m(2)), 67 years old, mostly female (57%), and had osteoarthritis (93%) as the primary indication for surgery. The material of the femoral head (metal, ceramic) was crossed with head size (< 32, 32, 36, > 36 mm), yielding eight device groupings. Only uncemented devices were evaluated. The primary outcome was all-cause revision (n = 28,772) and the secondary outcome was dislocation within 1 year (n = 19,623). Propensity scores were used to adjust for potential confounding at the implant/patient level using between-within semiparametric survival models that control for surgeon and hospital confounding and adjust estimates for the within-cluster correlation among observations on the response. Results For all-cause revision, there was no difference between ceramic versus metal (reference) heads in combination with an HXLPE liner (hazard ratio [HR] = 0.82 [0.65-1.04], p = 0.099). Smaller metal head sizes of < 32 mm were associated with increased risk of revision relative to 36 mm (HR = 1.66 [1.20-2.31], p = 0.002, adjusted p = 0.025). For dislocation, ceramic heads increased risk relative to metal at < 32 mm only (HR = 4.39 [1.72-11.19], p = 0.002, adjusted p = 0.020). Head sizes < 32 mm were associated with increased risk of dislocation relative to 36 mm for metal (HR = 2.99 [1.40-6.39], p = 0.005, adjusted p = 0.047) and ceramic heads (HR = 15.69 [6.07-40.55], p < 0.001, adjusted p < 0.001). Conclusions The results did not provide evidence for use of one femoral head material over another when used with HXLPE liners for the outcome of revision, but for dislocation, metal performed better than ceramic with < 32-mm heads. Overall, the findings suggest increased risk of revision/dislocation with head sizes < 32 mm.

Metrics

9 Record Views
24 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Industry collaboration
Domestic collaboration
Web of Science research areas
Orthopedics
Surgery
Logo image