Logo image
Longitudinal histomechanical heterogeneity of the internal thoracic artery
Journal article   Open access   Peer reviewed

Longitudinal histomechanical heterogeneity of the internal thoracic artery

Colton J. Kostelnik, Kiersten J. Crouse, Wayne Carver and John F. Eberth
Journal of the mechanical behavior of biomedical materials, v 116, 104314
01 Apr 2021
PMID: 33476887
url
https://doi.org/10.1016/j.jmbbm.2021.104314View
Published, Version of Record (VoR) Restricted

Abstract

Bypass grafting Internal mammary Porcine xenograft Vascular mechanics
The internal thoracic artery (ITA) is the principal choice for coronary artery bypass grafting (CABG) due to its mechanical compatibility, histological composition, anti-thrombogenic lumen, and single anastomotic junction. Originating at the subclavian artery, traversing the thoracic cavity, and terminating at the superior epigastric and musculophrenic bifurcation, bilateral ITAs follow a protracted circuitous pathway. The physiological hemodynamics, anatomical configuration, and perivascular changes that occur throughout this length influence the tissue's microstructure and gross mechanical properties. Since histomechanics play a major role in premature graft failure we used inflation-extension testing to quantify the regional material and biaxial mechanical properties at four distinct locations along the left (L) and right (R) ITA and fit the results to a structurally-motivated constitutive model. Our comparative analysis of 44 vessel segments revealed a significant increase in the amount of collagen but not smooth muscle and a significant decrease in elastin and elastic lamellae present with distance from the heart. A subsequent decrease in the total deformation energy and isotropic contribution to the strain energy was present in the LITA but not RITA. Circumferential stress and compliance generally decreased along the length of the LITA while axial stress increased in the RITA. When comparing RITAs to LITAs, some morphological and histological differences were found in proximal sections while distal sections revealed differences predominantly in compliance and axial stress. Overall, this information can be used to better guide graft selection, graft preparation, and xenograft-based tissue-engineering strategies for CABG.

Metrics

3 Record Views
4 citations in Scopus

Details

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Web of Science research areas
Engineering, Biomedical
Materials Science, Biomaterials
Logo image