Journal article
Optimizing patient positioning for intensity modulated radiation therapy in hippocampal-sparing whole brain radiation therapy
Practical radiation oncology, v 4(6), pp 378-383
01 Nov 2014
PMID: 25407858
Featured in Collection : UN Sustainable Development Goals @ Drexel
Abstract
Sparing the hippocampus during whole brain radiation therapy (WBRT) offers potential neurocognitive benefits. However, previously reported intensity modulated radiation therapy (IMRT) plans use multiple noncoplanar beams for treatment delivery. An optimized coplanar IMRT template for hippocampal-sparing WBRT would assist in clinical workflow and minimize resource utilization. In this study, we sought to determine the optimal patient position to facilitate coplanar treatment planning and delivery of hippocampal-sparing WBRT using IMRT.
A variable angle, inclined board was utilized for patient positioning. An anthropomorphic phantom underwent computed tomography simulation at various head angles. The IMRT goals were designed to achieve target coverage of the brain while maintaining hippocampal dose-volume constraints designed to conform to the Radiation Therapy Oncology Group 0933 protocol. Optimal head angle was then verified using data from 8 patients comparing coplanar and noncoplanar WBRT IMRT plans.
Hippocampal, hippocampal avoidance region, and whole brain mean volumes were 1.1 cm(3), 12.5 cm(3), and 1185.1 cm(3), respectively. The hippocampal avoidance region occupied 1.1% of the whole brain planning volume. For the 30-degree head angle, a 7-field coplanar IMRT plan was generated, sparing the hippocampus to a maximum dose of 14.7 Gy; D100% of the hippocampus was 7.4 Gy and mean hippocampal dose was 9.3 Gy. In comparison, for flat head positioning the hippocampal Dmax was 22.9 Gy with a D100% of 9.2 Gy and mean dose of 11.7 Gy. Target coverage and dose homogeneity was comparable with previously published noncoplanar IMRT plans.
Compared with conventional supine positioning, an inclined head board at 30 degrees optimizes coplanar whole brain IMRT treatment planning. Clinically acceptable hippocampal-sparing WBRT dosimetry can be obtained using a simplified coplanar plan at a 30-degree head angle, thus obviating the need for complex and time consuming noncoplanar IMRT plans.
Metrics
Details
- Title
- Optimizing patient positioning for intensity modulated radiation therapy in hippocampal-sparing whole brain radiation therapy
- Creators
- Joshua Siglin - Thomas Jefferson UniversityColin E Champ - Thomas Jefferson UniversityYelena Vakhnenko - Thomas Jefferson UniversityMatthew E Witek - Thomas Jefferson UniversityCheng Peng - Thomas Jefferson UniversityNicholas G Zaorsky - Thomas Jefferson UniversityAmy S Harrison - Thomas Jefferson UniversityWenyin Shi - Thomas Jefferson University
- Publication Details
- Practical radiation oncology, v 4(6), pp 378-383
- Publisher
- Elsevier
- Resource Type
- Journal article
- Language
- English
- Academic Unit
- Radiation Oncology (and Nuclear Medicine)
- Web of Science ID
- WOS:000422349000013
- Scopus ID
- 2-s2.0-84912529859
- Other Identifier
- 991021897396704721
UN Sustainable Development Goals (SDGs)
This publication has contributed to the advancement of the following goals:
InCites Highlights
Data related to this publication, from InCites Benchmarking & Analytics tool:
- Web of Science research areas
- Oncology
- Radiology, Nuclear Medicine & Medical Imaging