Logo image
Prospective Evaluation of Distal Radius Fractures Treated With Variable-Angle Volar Locking Plates
Journal article   Peer reviewed

Prospective Evaluation of Distal Radius Fractures Treated With Variable-Angle Volar Locking Plates

John R. Fowler and Asif M. Ilyas
The Journal of hand surgery (American ed.), v 38A(11), pp 2198-2203
01 Nov 2013
PMID: 24206983

Abstract

Life Sciences & Biomedicine Orthopedics Science & Technology Surgery
Purpose To evaluate the radiographic, objective (range of motion and grip strength), and subjective outcomes of variable-angle volar locking plate (VAVLP) fixation for unstable distal radius fractures. Methods Over a 12-month period, we prospectively evaluated 39 consecutive distal radius fractures treated operatively with VAVLPs. Surgical exposure, fracture reduction, plate application, and postoperative rehabilitation were uniformly performed. Clinical outcome and radiographic measures, with a minimum follow-up of 12 months, were obtained. Results Final follow-up data were available in 37 patients (26 females and 11 males) with average age of 57 years (range, 16-89 y). The average follow-up time was 14 months (range, 12-22 mo). At final evaluation, average volar tilt was 3 degrees, average radial inclination was 21 degrees, average radial height was 12 mm, and average ulnar variance was -0.2 mm. There was no statistical difference between first postoperative and 1-year follow-up radiographs for any of the measured variables, although there were 4 cases of loss of volar tilt. Average Disabilities of the Arm, Shoulder, and Hand score was 6 and average visual analog scale pain score was 0.3. Mean grip strength at 1 year was 96% of the contralateral side. There was 1 case of variable-angle locking screw loosening and 1 case of extensor tenosynovitis requiring hardware removal. There were no tendon ruptures. Conclusions The VAVLP fixation restored and maintained acceptable reduction in all patients in this series with a complication rate comparable to standard volar fixed-angle locking plates. Treatment of unstable distal radius fractures with a VAVLP resulted in excellent clinical outcomes at 1-year follow-up. However, use of the VAVLP risks soft tissue irritation, hardware failure, and loss of fracture reduction. Copyright (C) 2013 by the American Society for Surgery of the Hand. All rights reserved.

Metrics

7 Record Views
25 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#5 Gender Equality

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Domestic collaboration
Web of Science research areas
Orthopedics
Surgery
Logo image