Journal article
Reflex and functional responses to distal tibial/medial plantar nerve electrical stimulation in the treadmill-locomoting spinal cat
Journal of neurophysiology, v 136(3), pp 1246-1265
17 Aug 2026
PMID: 42606931
Abstract
Low-intensity electrical stimulation of the distal tibial nerve innervating the plantar foot with pulse trains promotes extensor activity in reduced animal preparations when delivered during the extensor phase. Since enhancing extensor activity could potentially improve weight support after spinal cord injury (SCI), we evaluated whether electrical stimulation of the distal tibial nerve or its medial plantar branch enhances/prolongs extensor activity in a locomotor-trained feline model of SCI. With stimulation trains at levels activating large-diameter afferents (low-threshold cutaneous/muscle group I afferents) we found no effects on the activity of the extensors and flexors during walking, whereas stimulation levels activating smaller fibers (higher-threshold cutaneous/muscle group II) were found to increase swing height for stimuli delivered in late stance/early swing. A further increase in stimulus intensity to levels recruiting noxious afferents terminated ongoing stance and produced a flexor withdrawal response of the paw. Muscle reflex responses to low-intensity single-pulse stimuli during walking showed a short-latency inhibition in extensor muscles followed by a longer-latency excitatory response when stimulation was delivered during stance and limited responses when delivered during swing. Flexors showed an early-latency excitatory response followed by a weak inhibitory response for stimulation delivered throughout most of the walking cycle. These reflex responses to single-pulse stimulation agreed with prior studies. The absence of extensor activity enhancement with low-intensity train stimulation of the distal tibial nerve during stance observed in other preparations may be partially explained by changes in spinal neuronal properties and locomotor networks in chronic spinal cats.
Contrary to prior results in the decerebrated feline, there was no enhancement of hindlimb extensor activity in response to activation of low-threshold cutaneous and proprioceptive afferents from the plantar foot by stimulation trains applied to the distal tibial nerve during stance in locomotor-trained spinal cats. This result may be partially explained by changes in spinal neural networks and suggests limited applicability of plantar foot stimulation for enhancing body weight support in locomotor-trained individuals with spinal injury.
Metrics
1 Record Views
Details
- Title
- Reflex and functional responses to distal tibial/medial plantar nerve electrical stimulation in the treadmill-locomoting spinal cat
- Creators
- Bernard J Krasnisky - Temple UniversityDavid P Kowalski - Drexel UniversityKaren Ollivier-Lanvin - Department of Neurobiology and Anatomy, Drexel University College of Medicine, Philadelphia, Pennsylvania, United StatesDaniel J Reiners - Temple UniversityBoris I Prilutsky - Georgia Institute of TechnologyMichel A Lemay - Temple University
- Publication Details
- Journal of neurophysiology, v 136(3), pp 1246-1265
- Publisher
- American Physiological Society (APS)
- Number of pages
- 20
- Grant note
- R01 NS110605 / NINDS NIH HHS ECCS-2024414 / NSF | ENG | Division of Electrical, Communications and Cyber Systems (ECCS) R01 EB012855 / NIBIB NIH HHS NS110605 / HHS | NIH | National Institute of Neurological Disorders and Stroke (NINDS) P01 NS055976 / NINDS NIH HHS EB012855 / HHS | NIH | National Institute of Biomedical Imaging and Bioengineering (NIBIB) R56 NS110605 / NINDS NIH HHS NS055976 / HHS | NIH | National Institute of Neurological Disorders and Stroke (NINDS)
- Resource Type
- Journal article
- Language
- English
- Academic Unit
- School of Biomedical Engineering and Science
- Web of Science ID
- WOS:001881363900002
- Other Identifier
- 991022207139704721