Abstract

PURPOSETypically, the kinetics of membrane transport is analyzed using the steady-state Michaelis-Menten (or Eadie-Hofstee or Hanes) equations. This approach has been successful when the substrate is picked up from the aqueous phase, like a water-soluble enzyme, for which the Michaelis-Menten steady-state analysis was developed. For membrane transporters whose substrate resides in the lipid bilayer of the plasma membrane, like P-glycoprotein (P-gp), there has been no validation of the accuracy of the steady-state analysis because the elementary rate constants for transport were not known.METHODSRecently, we fitted the mass action elementary kinetic rate constants of P-gp transport of three different drugs through a confluent monolayer of MDCKII-hMDR1 cells. With these elementary rate constants in hand, we use computer simulations to assess the accuracy of the steady-state Michaelis-Menten parameters. This limits the simulation to parameter ranges known to be physiologically relevant.RESULTSUsing over 2,300 different vectors of initial elementary parameters spanning the space bounded by the three drugs, which defines 2,300 "virtual substrates", the concentrations of substrate transported were calculated and fitted to Eadie-Hofstee plots. Acceptable plots were obtained for 1,338 cases.CONCLUSIONThe fitted steady-state Vmax values from the analysis correlated to within a factor of 2-3 with the values predicted from the elementary parameters. However, the fitted Km value could be generated by a wide range of underlying "molecular" Km values. This is because of the convolution of the drug passive permeability kinetics into the fitted Km. This implies that Km values measured in simpler systems, e.g., microsomes or proteoliposomes, even if accurate, would not predict the Km values for the confluent monolayer system or, by logical extension, in vivo. Reliable in vitro-in vivo extrapolation seems to require using the elementary rate constants rather than the Michaelis-Menten steady-state parameters.

Metrics

7 Record Views
51 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Industry collaboration
Domestic collaboration
International collaboration
Web of Science research areas
Chemistry, Multidisciplinary
Pharmacology & Pharmacy
Logo image