Visual attention on a respiratory function monitor during simulated neonatal resuscitation: an eye-tracking study
Journal article   Open access   Peer reviewed

Visual attention on a respiratory function monitor during simulated neonatal resuscitation: an eye-tracking study

Trixie A Katz, Danielle D Weinberg, Claire E Fishman, Vinay Nadkarni, Patrice Tremoulet, Arjan B te Pas, Aleksandra Sarcevic and Elizabeth E Foglia
Archives of disease in childhood. Fetal and neonatal edition, v 104(3), pp F259-F264
May 2019
PMID: 29903721
url
https://doi.org/10.1136/archdischild-2017-314449View
Published, Version of Record (VoR) Open

Abstract

ObjectiveA respiratory function monitor (RFM) may improve positive pressure ventilation (PPV) technique, but many providers do not use RFM data appropriately during delivery room resuscitation. We sought to use eye-tracking technology to identify RFM parameters that neonatal providers view most commonly during simulated PPV.DesignMixed methods study. Neonatal providers performed RFM-guided PPV on a neonatal manikin while wearing eye-tracking glasses to quantify visual attention on displayed RFM parameters (ie, exhaled tidal volume, flow, leak). Participants subsequently provided qualitative feedback on the eye-tracking glasses.SettingLevel 3 academic neonatal intensive care unit.ParticipantsTwenty neonatal resuscitation providers.Main outcome measuresVisual attention: overall gaze sample percentage; total gaze duration, visit count and average visit duration for each displayed RFM parameter. Qualitative feedback: willingness to wear eye-tracking glasses during clinical resuscitation.ResultsTwenty providers participated in this study. The mean gaze sample captured wa s 93% (SD 4%). Exhaled tidal volume waveform was the RFM parameter with the highest total gaze duration (median 23%, IQR 13–51%), highest visit count (median 5.17 per 10 s, IQR 2.82–6.16) and longest visit duration (median 0.48 s, IQR 0.38–0.81 s). All participants were willing to wear the glasses during clinical resuscitation.ConclusionWearable eye-tracking technology is feasible to identify gaze fixation on the RFM display and is well accepted by providers. Neonatal providers look at exhaled tidal volume more than any other RFM parameter. Future applications of eye-tracking technology include use during clinical resuscitation.

Metrics

14 Record Views
35 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#4 Quality Education

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Domestic collaboration
International collaboration
Web of Science research areas
Pediatrics
Logo image