Logo image
Ductility evaluation for typical existing R /C bridge columns in the eastern USA
Journal article   Peer reviewed

Ductility evaluation for typical existing R /C bridge columns in the eastern USA

Ali M. Memari, Harry G. Harris, Ahmad A. Hamid and Andrew Scanlon
Engineering structures, v 27(2), pp 203-212
2005

Abstract

Bridge columns Ductility Low to moderate seismicity Pushover analysis Reinforced concrete Response modification factor
Results of nonlinear static pushover analyses of five bridges located in Pennsylvania are presented. The bridges, which vary from single column bents to multiple column bents, have reinforced concrete columns with ties at 12 in. spacing. The objective of the part of the study that is presented in the paper is to estimate displacement ductility and force reduction factors for the selected bridges. The procedures used to obtain moment–curvature relations and to perform nonlinear static pushover analysis using linear elastic analysis software are described. Calculated values for displacement ductility factors and response modification factors ( R -values) are presented. Observations made from the results of a literature review on experimental evidence for ductility of deficient columns are also discussed.

Metrics

4 Record Views
10 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#11 Sustainable Cities and Communities

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Domestic collaboration
Web of Science research areas
Engineering, Civil