Integrated long‐term multifunctional pediatric mechanical circulatory assist device

Harutyun Sarkisyan, Randy Stevens, Vakhtang Tchantchaleishvili, Joseph Rossano and Amy Throckmorton
Artificial organs, v 45(5), pp E65-E78
May 2021
PMID: 33191508
url
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127979View
Accepted (AM)Open Access (License Unspecified) Open

Abstract

blood pump mechanical circulatory assistance pediatric circulatory support rotary blood pump Taguchi Design Optimization Method total artificial heart ventricular assist device
There continues to be limited, viable ventricular assist device technology options to support the dysfunctional states of pediatric heart failure. To address this need, we are developing a magnetically suspended, versatile pumping technology that uniquely integrates two blood pumps in a series configuration within a single device housing. This device enables operational switching from the usage of one pump to another as needed for clinical management or to support growth and development of the pediatric patient. Here, we present the initial design where we conducted a virtual fit study, the Taguchi Design Optimization Method, iterative design to develop pump geometries. Computational tools were used to estimate the pressure generation, capacity delivery, hydraulic efficiency, fluid stress levels, exposure time to stresses, blood damage index, and fluid forces on the impellers. Prototypes of the pumps were tested in a flow loop using a water‐glycerin solution. Both designs demonstrated the capability to generate target pressures and flows. Blood damage estimations were below threshold levels and achieved design requirements; however, maximum scalar stress levels were above the target limit. Radial and axial forces were less than 1 N and 10 N, respectively. The performance data trends for physical prototypes correlated with theoretical expectations. The centrifugal prototype was able to generate slightly higher pressure rises than numerical predictions. In contrast, the axial prototype outperformed the computational studies. Experimental data were both repeatable and reproducible. The findings from this research are promising, and development will continue.

Metrics

8 Record Views
8 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Collaboration types
Domestic collaboration
Web of Science research areas
Engineering, Biomedical
Transplantation
Logo image