Logo image
Methods of failure and reliability assessment for mechanical heart pumps
Journal article   Peer reviewed

Methods of failure and reliability assessment for mechanical heart pumps

Sonna M Patel, Paul E Allaire, Houston G Wood, Amy L Throckmorton, Curt G Tribble and Don B Olsen
Artificial organs, v 29(1), pp 15-25
Jan 2005
PMID: 15644079

Abstract

Guidelines as Topic Animals Equipment Failure Analysis - methods Humans Materials Testing Clinical Trials as Topic - standards Heart-Assist Devices
Artificial blood pumps are today's most promising bridge-to-recovery (BTR), bridge-to-transplant (BTT), and destination therapy solutions for patients suffering from intractable congestive heart failure (CHF). Due to an increased need for effective, reliable, and safe long-term artificial blood pumps, each new design must undergo failure and reliability testing, an important step prior to approval from the United States Food and Drug Administration (FDA), for clinical testing and commercial use. The FDA has established no specific standards or protocols for these testing procedures and there are only limited recommendations provided by the scientific community when testing an overall blood pump system and individual system components. Product development of any medical device must follow a systematic and logical approach. As the most critical aspects of the design phase, failure and reliability assessments aid in the successful evaluation and preparation of medical devices prior to clinical application. The extent of testing, associated costs, and lengthy time durations to execute these experiments justify the need for an early evaluation of failure and reliability. During the design stages of blood pump development, a failure modes and effects analysis (FMEA) should be completed to provide a concise evaluation of the occurrence and frequency of failures and their effects on the overall support system. Following this analysis, testing of any pump typically involves four sequential processes: performance and reliability testing in simple hydraulic or mock circulatory loops, acute and chronic animal experiments, human error analysis, and ultimately, clinical testing. This article presents recommendations for failure and reliability testing based on the National Institutes of Health (NIH), Society for Thoracic Surgeons (STS) and American Society for Artificial Internal Organs (ASAIO), American National Standards Institute (ANSI), the Association for Advancement of Medical Instrumentation (AAMI), and the Bethesda Conference. It further discusses studies that evaluate the failure, reliability, and safety of artificial blood pumps including in vitro and in vivo testing. A descriptive summary of mechanical and human error studies and methods of artificial blood pumps is detailed.

Metrics

10 Record Views
30 citations in Scopus

Details

UN Sustainable Development Goals (SDGs)

This publication has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

InCites Highlights

Data related to this publication, from InCites Benchmarking & Analytics tool:

Web of Science research areas
Engineering, Biomedical
Transplantation
Logo image